  1. Diagnosed loss of prime on an older jet pump well system

  2. Found cracked galvanized fittings causing pressure loss

  3. Removed old ejectors and foot valve from the well

  4. Installed new brass ejector package

  5. Replaced outdated galvanized fittings with new brass and stainless steel fittings

  6. Installed a new well seal and brought the well up to current code requirements

  7. Replaced damaged concrete well lid with a new lid

  8. Performed a full well yield test

  9. Shock chlorinated, flushed, and tested the system upon completion

  10. Tagged and registered the well and supplied the customer with a well report